Storm Drainage Systems
Storm drains are designed to carry clear water
waste from rain water and some specialty fixtures. Typically, large
flat roofs will require a storm drainage system to remove trapped
water, as the weight of the water could quickly damage the structure of
the roof in a heavy rainfall; to prevent this, rain water roof drains are installed to drain the water to a leader, then to a
storm building drain and finally to the public storm water disposal
system.
In residential construction storm water is less of a concern but still requires some provisions to prevent basements from flooding. When foundation walls are completed, a perforated pipe called weeping tile, is placed around the footing that will remove any ground water before it can penetrate the foundation. Gutters and downspouts may also be connected to the weeping tile or drained away from the foundation. Weeping tile; where available, is connected to a public storm system, but in rural area's the water must be drained to a low area; such as a ditch, french drain or pumped away with a sump system.
Components of a Storm Water Drainage System
Roof drains
Roof
drains come in dozens of different types and configurations to
suit any conceivable situation but there are two basic types;
normal, which are completely open, and flow controlled, which
limit the amount of water drained. The area of a flat roof and
the maximum 15 minute rainfall for the area will determine the
size and spacing of
roof drains.
Rain water leaders
A rain water leader is the vertical drain(including any horizontal offsets) that carries rain water and clear water waste to the storm building drain. Rain water leaders are sized by the amount of water(in Litres) they are expected to capable of draining. Leaders must be designed so that the expansion and contraction from intermittent temperature changes will not damage the piping system. As with sanitary drains, all rain water leaders must also be provided with a clean-out located close to the base of the leader(within 3M).
Storm building drain
A storm building drain will convey storm water from a leader or sump to a storm sewer, combined building drain/sewer, or a suitable location(ditch). Storm building drains are sized according to the maximum rainfall in Litres, and graded according to the size and load of the pipe. The storm building drain extends one meter outside the building where it then becomes a storm sewer.
Storm sewer
A storm sewer is the extension of a storm building drain beginning one meter outside the building. A storm sewer will discharge the water to a public storm system or another appropriate place where the water can be safely drain away. Because storm drains are not allowed to convey sewage, they are permitted to be drain to any area capable of handling the discharge.
Combined building drain / sewer
The term combined, whether referring to the building drain or the building sewer, simply means that the storm and sanitary drains are connected together. A combined building drain is connected together inside the building and a combined building sewer makes the connection more than one meter from the exterior of a building.
Connecting plumbing fixtures to a storm drain
In commercial / industrial buildings there may be numerous fixtures that discharge clear water waste and is not required to be treated. These fixtures may be indirectly connected to a storm drainage system(check your local code). Fixtures connected to a storm system must have their discharge rates calculated so the drains can be sized (usually given in Litres per second or Gpm). Some fixtures that typically discharge clear water waste are:
- Kitchen equipment
- Air conditioners
- Refrigeration equipment
- Drinking fountains